MODEL RANGE

No matter how big or small is your vessel, we have a waterjet model in our comprehensive range to suit. Understanding the application is a key factor in choosing the right waterjet; we work closely with you to appraise the optimum size waterjet and the configuration that best meets your budget requirements without compromising vessel capacity to sustainability perform its designated role.

Currently, there are twelve models within the Optima family suiting engine power up to 6500 kilowatts.

Please contact us and our engineering application dedicated team will assist you with the jet selection and all your technical inquiries.

 

 

DJ140HP-1200PX
OPTIMA SERIES MODELS
Waterjet Model DJ150HP DJ170HP DJ200 DJ220 DJ240 DJ260 DJ290 DJ310 DJ350 DJ400 DJ450
Impeller Size mm(in) 381 (15) 432 (17) 520 (20.5) 559 (22) 610 (24) 660 (26) 736 (29) 788 (31) 890 (35) 1015 (40) 1145 (45)
Max Rec. Power(1) kW(hp) 745 (1000) 970 (1300) 1265 (1700) 1450 (1950) 1775 (2380) 2010 (2700) 2535 (3400) 2900 (3900) 3725 (5000) 5350 (7150) 6500 (8700)
Maximun Rec. RPM(1) 2250 1975 1680 1525 1370 1290 1160 1085 970 850 750
Dry Weight(2) Kg 430 510 875 1050 1400 1700 2340 2780 3650 4900 6900
Jet Variants(3) DT, IWJ, HE DT, IWJ, HE DT, IWJ, HE DT, IWJ, HE DT, IWJ, HE DT, IWJ, HE DT, IWJ, HE B, DT B, DT B, DT B, DT
Dimensions(4)(mm) A 1105 1225 1420 1775 1695 1975 2195 2155 2415 2645 3075
B(5) 1420 1670 1935 2170 2315 2520 2850 3420 3520 4455 5000
C 755 815 1015 1210 1210 1365 1565 1590 1755 1725 2175
D(5) 320 350 430 460 510 540 600 640 685 785 880
E(5) 1225 1355 1540 1785 1835 1945 2195 2305 2630 3065 3445
F(5) 810 940 1100 1200 1315 1475 1700 1815 2040 2200 2200
G(5) 620 690 830 840 900 950 1040 1175 1250 1430 1610
H(5) 90* 90* 90* 90* 90* 90* 90* 90* 90* 90* 90*

Note

  1. Max Recommended Power/RPM for standard model (subject to application eng. review)
  2. Includes Std. Reverse Control System – Excludes Entrained Water
  3. DT: Direct Thrust | IWJ: Integrated Waterjet | HE: Hybrid Electric
  4. Typical only – not to be used for construction purposes
  5. Standard stated – tailor-made intake tunnel, narrow reverse bucket, and custom shaft angle available